Product description
The EA16 AVR is an update of the EA15A AVR. It is similar to the original EA15A in power and voltage sensing capabilities but with new enhanced paralleling functions; the user can now select the CT inputs either 1 & 5 Amp or use new A1 & A2 analogue signal inputs terminals for use with PLC paralleling controls. It has new over-voltage excitation safety circuits to prevent damage caused by the accidental detachment of the sensing wires or irregularities on the generator’s excitation circuits.
Main features:
1. Voltage regulation < ±0.5%
2. Suitable for brushless type generator sensing input 170~510VAC
3. Can be used in parallel operation
4. 16ADC current output
5. AVR16 suitable frequency 50/60Hz
6. AVR16-400Hz suitable frequency 400Hz
7. Soft start voltage ramping
8. Load CT current compensation, analogue voltage input
Specifications:
Sensing Input | Voltage 170~510 VAC single phase 2 wire |
Frequency 50/60 Hz | |
Power Input | Voltage 60~300 VAC single phase 2 wire |
Output | Voltage Max. 90 VDC @ 240 VAC input |
Voltage Regulation | < ±0.5% (with 4% engine governing) |
Voltage Build-up | Residual volts at AVR terminal > 5 VAC |
External Volts Adjustment | ±5% with 2 K Ohm 1 watt trimmer |
Unit Power Dissipation | Max. 10 watt |
Thermal Drift | 0.03% per °C change in AVR ambient |
Under Frequency Protection | 55 Hz @ 60 Hz / 45 Hz @ 55 Hz (Adjustable) |
CT Current Compensation Input | 1A or 5A (Selectable) |
Analogue Input | ±5 VDC ±10% AC @ ±3 VDC |
Environment | Operating Temperature : -40~70 °C |
AVR Controls Functions | VOLT : Voltage Adjustment |
Dimensions | 156.0 (L) x 106.0 (W) x 43.0 (H) mm |
Weight | 450g ±2% |