VR6/K65-12B Generator AVR

VR6/K65-12B Generator AVR

  • publish: 2021-01-15 17:00      Browse:
  • Type:     K65-12B
  • Product Summary:
  •       Description The K65-12B Voltage Regulator is contained in an encapsulated plastic case. sensing: 110VAC,output: 12A/65V .For 50 or 60 Hz brushless generators.The regulator includes frequency compensation with selectable slope, inverse time over-excitation shutdown, solid-state build-up circuitry, single-phase or three-phase voltage sensing, single-phase or three phase shunt, or permanent magnet power input, and parallel droop compensation, and an ...

Introduce
Product:
User manual:
Software Download:

Description

The K65-12B Voltage Regulator is contained in an encapsulated plastic case. sensing: 110VAC,output: 12A/65V .For 50 or 60 Hz brushless generators.The regulator includes frequency compensation with selectable slope, inverse time over-excitation shutdown, solid-state build-up circuitry, single-phase or three-phase voltage sensing, single-phase or three phase shunt, or permanent magnet power input, and parallel droop compensation, and an accessory input. The accessory input provides compatibility with accessories such as a var/power factor controller.

 

 Specification K65-12BK125-10B
 Output power(with a 240 Vac input) 12Adc @ 65 Vdc Max cfontainuous; 
 25 Adc @ 125 Vdc forcing for 10 
 seconds
 10 Adc @ 125 Vdc max continuous. 
 20 Adc @ 250 Vdc forcing for 10 
 Seconds.
 AC input power 100 to 280 Vac, single-phase 50 to 
 400 Hz; or 63 to 105 Vac three-
 Phase, 50 to 400 Hz; 1092 VA max 
 Continuous burden
 180 to 280 Vac, single-phase or 
 Three-Phase, 50 to 400 Hz, 1750 VA  
 Max Continous burden.
 AC  sensing voltage 90 to 140 Vac, 50/60 Hz; single-or-
 Three Phase.
 90 to 140 Vac, 50/60 Hz; single-or-
 Three Phase.
 External voltage adjust rheostat 10K ohm, 2W, potentiometer 10K ohm, 2W, potentiometer
 Regulation accuracy ±0.5% Average responding ±0.5% Average responding
 Voltage drift ±1% voltage variation for a 40 Deg. C 
 Change.
 ±1% voltage variation for a 40 Deg. C 
 Change.
 Response time <4 ms <4ms
 Frequency compensation 1 or 2 V/Hz jumper selectable with 
 Knee Adjustable from 45 Hz to 65 Hz
 1 or 2 V/Hz jumper selectable with 
 Knee Adjustable from 45 Hz to 65 Hz
 EMI suppression Internal filter Internal filter
 Voltage Build-Up Internal provisions for automatic 
 Voltage Build-up from generator 
 Residual voltages As low as six Vac
 Internal provisions for automatic 
 Voltage Build-up from generator 
 Residual voltages As low as six Vac
 Droop 1 A or 5 A,<10 VA,adjustable from 0 
 To 10% at rated input current, 0.38 
 Power Factor
 1 A or 5 A,<10 VA,adjustable from 0 
 To 10% at rated input current, 0.38 
 Power Factor
 Operating and storage temperature -40 Deg. C to +70 Deg.C -40 Deg. C to +70 Deg.C
 Shock: Withstands up to 20 g in each of 
 Three Mutually perpendicular axes
 Withstands up to 20 g in each of three 
 Mutually perpendicular axes
 Vibtation: Withstands the following 
 Accelerations at The stated 
 Frequency: 0.5g; 18 to 2000Hz
 Withstands the following 
 Accelerations at The stated 
 Frequency: 0.5g; 18 to 2000Hz