how to store and install the diesel genset with the controll
Q: how to store and install the diesel genset with the controller?
A:Because of the influence of the environment condition of diesel generator set is very large, so requires a series of standards for the environment.Diesel generating set power calibration by are specific to a particular environment, environment refers to the diesel generator set operating location falling in to the atmospheric pressure, and relative humidity environment, the following LIXISE details of diesel genset and controller for everybody storage, installation and use of location choice shall meet the following conditions:
A,The storage of diesel genset and installation method
1, the room is spacious and bright, good ventilation, low humidity, environment temperature < 40 ℃;
2, the environment should be clean, are not allowed to be placed around the produce the goods of acid and alkali corrosive gas;
Unit 3, such as not using fixed on the basis, can under your chassis with rubber to reduce vibration;
4, night work should have good lighting, outdoor use should add protective cover, to avoid the rain and the sun;
5, diesel engine exhaust pipe should be open, try to avoid pipe is too long or a sudden turn.When the exhaust pipe connected to outside, outside the pipe should be down a little, water out of the tube;
6, more than 30 kw units when installation should do the following:
1) in order to reduce environmental noise, the external quieter;
2) open cooling unit must be the other cooling water pipe, to ensure an adequate water supply;
3) the battery should be according to the start of the diesel engine maintenance instructions, the charging circuit diagram;
4) must be used when the installation level measuring levelness, guarantee the unit on the basis of fixed in a horizontal position;
5) foundation adopt concrete, but the foundation shall not and building foundation together.Building wall for unit distance so 1.5 meters;
6) is installed on diesel engine generator shaft shaft concentricity not generally should be less than 0.15 mm, generator axis of flywheel end dance in general should be less than 0.5/400;
7) for the sake of personal safety, generators and switch panel must be another earth wire, ground wire cross-sectional area area of not less than the generator output line.Ground to pick up on the underground water pipe or deeply buried steel, ensure good grounding, grounding resistance shall not be greater than 50 ohm;
Second, the genset controller working conditions and Storage conditions
Generating set controller general working environment: the temperature is in(-25~+70)ºC ,Relative humidity: (20 ~ 90) %, no condensation. Storage conditions: Temperature: (DHS C - 30 ~ + 80).
Summary:LIXISE is the use of improved generator controller in extreme circumstances, such as the use of the Antarctic region is extremely low temperatures, or high temperature environment, and used in the highlands, deep sea and other places of special environment, fully meet the needs of various special users.